SF6 Leakage Test Stand
Tightness tests can be conducted on rails with this test stand: the pressure is created by means of a pressure booster. The high-pressure medium contains SF6 and the smallest leakage is determined in the vacuum chamber via a suitable laser sensor. A Siemens PLC looks after the control. A touch panel serves as input and display device. Operation can also be handled via a keyboard. All relevant measuring results are visualised.
PERFORMANCE DATA:
- Test pressure up to 2,700 bar
- Pressure dwell time variable
- Leakage rate measurement
- Various test points configurable
- Automatic clamping