H2 Pipes – Lines for Hydrogen Applications
Poppe + Potthoff’s H2 pipes are designed for the safe supply and distribution of hydrogen in both mobile and stationary applications.

Specifications
The certified metallic compression head connection of the H2 lines ensures reliable reassembly.
By specifically varying the line dimensions, it is possible to optimally meet individual specifications and space requirements.
Illustration

Technical Data – PPH2-Lines
The following variants of PPH2 lines are currently undergoing validation.
Technical Data | |
---|---|
Inner diameter of the line | 4 mm |
Outer diameter of the line | 6.35 mm |
Line length | max. 1.5 m |
Material | PPH2* |
Surface protection | Zn, Zn-Ni |
Seal type | metallic |
Interfaces / Thread Specifications | |
Manufactured female interface (015403-B) | M15×1-6H |
Integrated female interface (016584-B) | M14×1.5-6H |
Operating Conditions | |
Operating temperature | -40 to +85 °C |
Nominal operating pressure (50,000 cycles) | up to 700 bar |
Burst pressure | > 3900 bar |
Medium | Hydrogen (CGH2) |
Leakage rate | < 10 Ncm³/h |
Technical Data | |
---|---|
Inner diameter of the line | 7 mm |
Outer diameter of the line | 10 mm |
Line length | max. 1.5 m |
Material | PPH2* |
Surface protection | Zn, Zn-Ni |
Seal type | metallic |
Interfaces / Thread Specifications | |
Manufactured female interface (015427-C) | M22×1.5-6H |
Integrated female interface (018230-B) | M16×1.5-6H |
Operating Conditions | |
Operating temperature | -40 to +85 °C |
Nominal operating pressure (50,000 cycles) | up to 350 bar |
Burst pressure | > 3000 bar |
Medium | Hydrogen (CGH2) |
Leakage rate | < 10 Ncm³/h |
Technical Data | |
---|---|
Inner diameter of the line | 6 mm |
Outer diameter of the line | 10 mm |
Line length | max. 1.5 m |
Material | PPH2* |
Surface protection | Zn, Zn-Ni |
Seal type | metallic |
Interfaces / Thread Specifications | |
Manufactured female interface (020538-A) | M22×1.5-6H |
Integrated female interface (020542-B) | M16×1.5-6H |
Operating Conditions | |
Operating temperature | -40 to +85 °C |
Nominal operating pressure (50,000 cycles) | up to 700 bar |
Burst pressure | > 4300 bar |
Medium | Hydrogen (CGH2) |
Leakage rate | < 10 Ncm³/h |
Technical Data | |
---|---|
Inner diameter of the line | 8 mm |
Outer diameter of the line | 12 mm |
Line length | max. 1.5 m |
Material | PPH2* |
Surface protection | Zn, Zn-Ni |
Seal type | metallic |
Interfaces / Thread Specifications | |
Integrated female interface (023790-B) | M22×1.5-6H |
Operating Conditions | |
Operating temperature | -40 to +85 °C |
Nominal operating pressure (50,000 cycles) | tbd |
Burst pressure | tbd |
Medium | Hydrogen (CGH2) |
Leakage rate | < 10 Ncm³/h |
Technical Data – H2 Lines made of Stainless Steel
The following variants of hydrogen lines made of stainless steel are currently undergoing validation.
Technical Data | |
---|---|
Inner diameter of the line | 3.15 mm |
Outer diameter of the line | 6.35 mm |
Line length | max. 1.5 m |
Material | 1.4435 |
Seal type | metallic |
Interfaces / Thread Specifications | |
Manufactured female interface (022465-A) | M15×1-6H |
Integrated female interface (022466-A) | M14×1.5-6H |
Male interface (023751-A) | M12×1.5-6H |
Operating Conditions | |
Operating temperature | −40 to +85 °C |
Nominal operating pressure (50,000 cycles) | tbd |
Burst pressure | tbd |
Medium | Hydrogen (CGH2) |
Leakage rate | < 10 Ncm³/h |
Technical Data | |
---|---|
Inner diameter of the line | 5.3 mm |
Outer diameter of the line | 10.3 mm |
Line length | max. 1.5 m |
Material | 1.4435 |
Seal type | metallic |
Interfaces / Thread Specifications | |
Male interface (023744-A) | M16×1.5-6H |
Integrated female interface (023743-A) | M16×1.5-6H |
Operating Conditions | |
Operating temperature | −40 to +85 °C |
Nominal operating pressure (50,000 cycles) | tbd |
Burst pressure | tbd |
Medium | Hydrogen (CGH2) |
Leakage rate | < 10 Ncm³/h |
Technical Data | |
---|---|
Inner diameter of the line | 7 mm |
Outer diameter of the line | 10 mm |
Line length | max. 1.5 m |
Material | 1.4435 |
Seal type | metallic |
Interfaces / Thread Specifications | |
Integrated female interface (018230-B) | M16×1.5-6H |
Operating Conditions | |
Operating temperature | −40 to +85 °C |
Nominal operating pressure (50,000 cycles) | tbd |
Burst pressure | tbd |
Medium | Hydrogen (CGH2) |
Leakage rate | < 10 Ncm³/h |
Safety Information
The lines may only be used after installation by qualified personnel in accordance with the corresponding installation instructions. Use for the manufacture of commercial goods is only permitted in certified countries. Otherwise, the product may only be used for testing purposes.
Note on PPH2 lines: For use with dry hydrogen only, in accordance with DIN EN 17124 (3.7 or higher). Due to the risk of corrosive effects, contact with moisture and/or water on the inner surface of the line must be strictly avoided under all circumstances.
Data Sheet PPH2-Lines
Data Sheet Lines made of Stainless Steel
Download Datasheet Lines made of Stainless Steel
Further Information on the TOPAQ Hydrogen Distribution System from Poppe + Potthoff