H2 Pipes – Lines for Hydrogen Applications

Poppe + Potthoff’s H2 pipes are designed for the safe supply and distribution of hydrogen in both mobile and stationary applications.

ENQUIRE NOW

Specifications

The certified metallic compression head connection of the H2 lines ensures reliable reassembly.

By specifically varying the line dimensions, it is possible to optimally meet individual specifications and space requirements.

Illustration

Technical Data – PPH2-Lines

The following variants of PPH2 lines are currently undergoing validation.

Technical Data
Inner diameter of the line 4 mm
Outer diameter of the line 6.35 mm
Line length max. 1.5 m
Material PPH2*
Surface protection Zn, Zn-Ni
Seal type metallic
Interfaces / Thread Specifications
Manufactured female interface (015403-B) M15×1-6H
Integrated female interface (016584-B) M14×1.5-6H
Operating Conditions
Operating temperature -40 to +85 °C
Nominal operating pressure (50,000 cycles) up to 700 bar
Burst pressure > 3900 bar
Medium Hydrogen (CGH2)
Leakage rate < 10 Ncm³/h
* PPH2 is a registered designation of Poppe + Potthoff Präzisionsstahlrohre GmbH.
Technical Data
Inner diameter of the line 7 mm
Outer diameter of the line 10 mm
Line length max. 1.5 m
Material PPH2*
Surface protection Zn, Zn-Ni
Seal type metallic
Interfaces / Thread Specifications
Manufactured female interface (015427-C) M22×1.5-6H
Integrated female interface (018230-B) M16×1.5-6H
Operating Conditions
Operating temperature -40 to +85 °C
Nominal operating pressure (50,000 cycles) up to 350 bar
Burst pressure > 3000 bar
Medium Hydrogen (CGH2)
Leakage rate < 10 Ncm³/h
* PPH2 is a registered designation of Poppe + Potthoff Präzisionsstahlrohre GmbH.
Technical Data
Inner diameter of the line 6 mm
Outer diameter of the line 10 mm
Line length max. 1.5 m
Material PPH2*
Surface protection Zn, Zn-Ni
Seal type metallic
Interfaces / Thread Specifications
Manufactured female interface (020538-A) M22×1.5-6H
Integrated female interface (020542-B) M16×1.5-6H
Operating Conditions
Operating temperature -40 to +85 °C
Nominal operating pressure (50,000 cycles) up to 700 bar
Burst pressure > 4300 bar
Medium Hydrogen (CGH2)
Leakage rate < 10 Ncm³/h
* PPH2 is a registered designation of Poppe + Potthoff Präzisionsstahlrohre GmbH.
Technical Data
Inner diameter of the line 8 mm
Outer diameter of the line 12 mm
Line length max. 1.5 m
Material PPH2*
Surface protection Zn, Zn-Ni
Seal type metallic
Interfaces / Thread Specifications
Integrated female interface (023790-B) M22×1.5-6H
Operating Conditions
Operating temperature -40 to +85 °C
Nominal operating pressure (50,000 cycles) tbd
Burst pressure tbd
Medium Hydrogen (CGH2)
Leakage rate < 10 Ncm³/h
* PPH2 is a registered designation of Poppe + Potthoff Präzisionsstahlrohre GmbH.

Technical Data – H2 Lines made of Stainless Steel

The following variants of hydrogen lines made of stainless steel are currently undergoing validation.

Technical Data
Inner diameter of the line 3.15 mm
Outer diameter of the line 6.35 mm
Line length max. 1.5 m
Material 1.4435
Seal type metallic
Interfaces / Thread Specifications
Manufactured female interface (022465-A) M15×1-6H
Integrated female interface (022466-A) M14×1.5-6H
Male interface (023751-A) M12×1.5-6H
Operating Conditions
Operating temperature −40 to +85 °C
Nominal operating pressure (50,000 cycles) tbd
Burst pressure tbd
Medium Hydrogen (CGH2)
Leakage rate < 10 Ncm³/h
Technical Data
Inner diameter of the line 5.3 mm
Outer diameter of the line 10.3 mm
Line length max. 1.5 m
Material 1.4435
Seal type metallic
Interfaces / Thread Specifications
Male interface (023744-A) M16×1.5-6H
Integrated female interface (023743-A) M16×1.5-6H
Operating Conditions
Operating temperature −40 to +85 °C
Nominal operating pressure (50,000 cycles) tbd
Burst pressure tbd
Medium Hydrogen (CGH2)
Leakage rate < 10 Ncm³/h
Technical Data
Inner diameter of the line 7 mm
Outer diameter of the line 10 mm
Line length max. 1.5 m
Material 1.4435
Seal type metallic
Interfaces / Thread Specifications
Integrated female interface (018230-B) M16×1.5-6H
Operating Conditions
Operating temperature −40 to +85 °C
Nominal operating pressure (50,000 cycles) tbd
Burst pressure tbd
Medium Hydrogen (CGH2)
Leakage rate < 10 Ncm³/h

Safety Information

The lines may only be used after installation by qualified personnel in accordance with the corresponding installation instructions. Use for the manufacture of commercial goods is only permitted in certified countries. Otherwise, the product may only be used for testing purposes.

Note on PPH2 lines: For use with dry hydrogen only, in accordance with DIN EN 17124 (3.7 or higher). Due to the risk of corrosive effects, contact with moisture and/or water on the inner surface of the line must be strictly avoided under all circumstances.

Data Sheet PPH2-Lines

Data Sheet Lines made of Stainless Steel

Get in contact: