TOPAQ On Tank Valve (OTV)

The On-Tank Valve (OTV) ensures safe refueling and gas extraction processes, as well as the storage of gas in stationary and mobile hydrogen (H₂) tanks.

ENQUIRE NOW

Technical Data and Specifications

With its optimized modular design, the On-Tank Valve allows for the fulfillment of individual customer requirements while complying with relevant legal standards (UN/ECE R134, HGV 3.1).

Illustration

Technical Data of the On Tank Valve

Technical data Operating conditions
Installation Space Diameter Ø 160 mm
OTV Height (Screwed In) 37.7 mm
OTV Height 202 mm
OTV Body Height 127 mm
OTV Weight approx. 1400 g
OTV Body Weight approx. 685 g
Tank Connection 1½″-12 UNF
OTV Body Material Anodized Aluminum
Sealing Types Metallic, O-Ring, PEEK
Operating Temperature −40 to +85 °C
Nominal Operating Pressure 700 bar
Maximum Allowable Operating Pressure 875 bar
Test Pressure 1050 bar
Kv-Value (Refueling / Extraction)* 0.18 / 0.10
Medium Hydrogen (CGH₂)
Leakage Rate (per UN/ECE R134) < 10 Ncm³/h
*Note: For an optimized flow during refueling and extraction, the hand valve must be fully opened.

Technical Data of Accessory Components

Technical data Operating conditions
Solenoid Valve
Operating Voltage 12 V or 24 V DC (PWM signal)
Temperature Sensor
Thermocouple Discrete NTC thermistor
Operating Temperature −60 to +150 °C
Thermal Pressure Relief Device (TPRD)
Activation Temperature 110 ±5 °C
Minimum Flow Diameter 4.4 mm
Flow Limiter
Activation Flow Rate (@ 20 bar / ambient temperature) 2.1 – 3.4 g/s
Filter Pore Size (Inlet / Outlet) 10 μm
Check Valve
Opening Pressure < 3 bar
Sealing Pressure ≥ 2 bar
Hand Valve / Vent Valve Activated by hexagon / square drive

Safety Information

The On-Tank Valve should only be used after installation by qualified personnel in accordance with the corresponding installation instructions. Use for the production of commercial goods is only permitted in certified countries. Otherwise, the product may only be used for testing purposes.